Playing with the Environment
Autodesk Forma Design Contest 2024
An entry for the Autodesk Forma Design Contest: a performance-driven mixed-use masterplan of five towers on the San Diego waterfront. The challenge was to use Forma in the early stages of a project, letting analysis of sun exposure, daylight, wind, noise and carbon guide the design.
Each building was shaped step by step: moved out of a neighbour’s shadow, reoriented, given a base and more height, and spaced from its twin tower until every face received good sunlight. Wind, noise and solar studies then checked the layout of the whole site.
- Year
- 2024
- Competition
- Autodesk Forma Design Contest 2024
- Site
- San Diego waterfront, USA
- Scheme
- Mixed-use masterplan, 5 towers
- Studies
- Sun hours, daylight, wind, noise, microclimate, solar
Site and climate baseline
Establishing seasonal sun exposure, wind comfort, acoustic perimeter, and summer heat stress before placing any massing.


Mapping road and highway noise impact across the site perimeter.
Baseline wind speeds remain within a comfortable pedestrian range.
Microclimate analysis showing moderate to strong heat stress during summer.
Massing by sun hours
Each tower was relocated, reshaped, and spaced step by step until every facade received strong winter sunlight.
Building 01
Limited natural daylight along the north facade.
Adjusting the massing improved daylighting, though overshadowing from the adjacent building persisted.
Relocating the tower out of the neighbouring shadow zone, informed by surrounding studies.
Building 02


Building 03
Final sun hours: winter vs. summer
Matching camera angles paired directly between 21 January and 20 August to verify year-round solar access.


Daylight potential
Checking vertical sky component and interior daylight reach across every tower elevation.
Wind comfort & streamlines
Testing pedestrian-level comfort across landscaped plazas and tracking turbulence across massing iterations.
Acoustic buffering
Using perimeter tower placement to shield the central park from surrounding arterial traffic noise.
Solar energy potential
Evaluating rooftop versus facade photovoltaic feasibility across the five-tower scheme.
Rooftop solar potential is strong across the scheme, making roof-mounted PV arrays highly viable.
Facade solar yield is lower, making building-integrated PV viable only on select high-exposure elevations.
Final massing & area metrics
Five mixed-use towers organized around a sheltered central park on the San Diego waterfront.
- Site area
- 1,659,339 ft²
- Building coverage (BC)
- 35% · 577,424 ft²
- Total GFA
- 3,045,700 ft² (184%)
- Residential
- 1,154,299 ft²
- Hospitality
- 933,148 ft²
- Commercial
- 670,817 ft²
- Office
- 287,436 ft²
- FAR
- 1.84
- Efficiency factor
- 0.90